RX560-MD Rahmen / Bezel
The RX560 MammoDuo consists of two RX560 monitors that are combined next to one another in a specially designed stand.
A New Level of Observation, Without Disruptive Factors

With a bezel only 7.5 mm in width – the world’s smallest bezel width for 5-megapixel monitors – the distance between the display areas of the two monitors is merely 15 mm. Moreover, the panel frame is only 2.5 mm above the screen, which means it sits nearly flush with the screen. This means viewers’ vision goes undisrupted when looking back and forth between the monitors.


Space-saving Arrangement

The RX560 MammoDuo saves a great deal of space. This solution saves 67 mm horizontally, 36 mm vertically, and 20.5 mm in depth, compared to conventional structures built from individual monitors with this resolution arranged next to one another. In sum, this means a 22% reduction of the total required surface. This frees up valuable space to make for a roomier working environment.

RX560-MD
RX560-MD_Workspace

Easily Adjustable

You can conveniently adjust the height, tilt, and rotation of the monitors with the dual stand, without creating gaps between the monitors.

RX560_MD_top_down
RX560-MD_Swifle

RX560-MD Medical Monitor
Perfectly Designed for Diagnostic Use

Narrow black frontal bezels make this device ideal for use in dark environments. They make it easy to visually concentrate on the display. Meanwhile, a white bezel at the sides of the monitors creates a fresh, clean look.


Work-and-Flow, Innovations to Help You View Your Images

Radiologists face an increasing amount of information on their screens, as modalities become increasingly digitalized. But imaging procedures now no longer need to be so complex, thanks to the unique Work-and-Flow technology from EIZO, featuring new functions developed specially to meet the requirements of radiologists. The RadiForce RX560-MD and RadiCS-LE software solution enable you to benefit from the Work-and-Flow functions.

Point and Focus: Easily Select the Analysis Area

The ‘point and focus’ functionality allows you to quickly select and focus on relevant image areas using your mouse or keyboard. The brightness and grayscale value of certain points on the screen can be adapted, if necessary, in order to optimize the display.

Point-and-Focus RX560-MD
"‘Point and focus’ allows users to quickly select and focus on relevant areas of observation using their mouse or keyboard. "

Full Color Support for Ultrasound, Breast CTs, and MRIs

Mammography is increasingly being combined with ultrasound scans in early breast cancer detection, particularly for patients with a high breast density. Moreover, in cases of suspected breast cancer, additional methods such as biopsies, breast MRIs, and computer tomography are used.

The RadiForce RX560 is the world’s first medical monitor that uses an LCD on an LTPS (low-temperature polysilicon) basis. This allows the color monitor to achieve a brightness of up to 1100 cd/m2, comparable to that of a monochrome monitor. As a result, the RX560 is able to display high-resolution breast tomosynthesis images as well as mammograms with deep, non-faded black tones as well as color images from ultrasound scans and pathology examinations.

A high contrast ration of 1500:1, close to that of a monochrome monitor, means that deep black tones can also be reproduced without a ‘washing out’ effect.

Monochrome und farbige Bilder mit nur einem Monitor betrachten
Full Color Support for Ultrasound, Breast CTs, and MRIs

Observe Monochrome and Color Images on a Single Monitor

The hybrid gamma PXL functionality automatically differentiates between monochrome and color images, pixel by pixel. This creates a hybrid display on which each pixel is displayed with the ideal tone value. In turn, this achieves a greater degree of precision and reliability than for conventional planar detection methods.

The RX560 reproduces sophisticated monochrome images from breast tomography or mammography as reliably as color images from breast MRIs or CTs, ultrasound scans, and pathology. In practical application, this means a significant increase in efficiency, since images from various imaging methods can be observed on a single monitor.

Funkce Hybrid Gamma PXL automaticky pixel po pixelu rozlišuje mezi monochromatickým a barevným obrazem.
The hybrid gamma PXL functionality automatically differentiates between monochrome and color images, pixel by pixel.

Multi-monitor solutions without problems

Thanks to the signal input and output, you can link several RadiForce monitors through their DisplayPort interface. This means that you can realize multi-monitor solutions with the greatest of ease – without laborious and excessive cabling.

Daisy Chain RadiForce

Blur reduction

LCD panels with a high brightness level tend to have more blurry image rendering thanks to over-framing than would be possible in comparison with an acquired exposure. Therefore, EIZO offers blur reduction anchored in monitor hardware. It retrieves details lost in the contours on the screen, meaning that the image is rendered as clearly as possible.

Erklärung Unschärfe Reduzierung

Sharp, High-resolution Images

The monitor has a pixel width of 0.165 mm and thereby reproduces even, high-resolution, sharp, and high-depth images without any kind of granularity. 


Secure image quality thanks to AAPM/Euref/DIN compliance

The display properties, in particular brightness and contrast, are suited to the creation of image rendering systems compliant with DIN 6868-157. The DICOM GSDF characteristic is already precisely configured in the factory. This means that grayscales are consistent, which is vital for diagnostics.

The monitor meets the strictest medical, safety, and EMC emission standards. EIZO’s QC software RadiCS enables you to perform brightness, grayscale and uniformity checks that comply with AAPM TG18, DIN 6868-157, and other QC standards.

Overview RadiCS application classes I to VIII

Foto: Bildqualität durch DIN-Konformitaet
Foto: Bildqualität durch DIN-Konformitaet

Balanced image quality thanks to an integrated front sensor

The precise calibration of white point and tone value characteristic curve is provided by an integrated front sensor (IFS). This measures the brightness and grayscales and calibrates the monitor autonomously according to the DICOM standard. The sensor works automatically, without restricting the field of vision of the monitor. You can save the costs, time, and effort of maintenance and rely on a consistently balanced image quality. 

No IFS
Without IFS
With IFS
With IFS

One Billion Hues, Thanks to the 12-bit Look-up-table

Precise color reproduction is controlled via a 12-bit look-up table (LUT). A maximum of 10-bit resolution, or up to one billion hues, is available via DisplayPort. This ensures flawless color reproduction of MRI, ultrasound, and pathology images. As such, the recording curve and microstructures required for diagnosis can be precisely detected. 


Foto: Konstante Helligkeit
Constant brightness during operation

A sensor for the backlight permanently determines the luminance of the monitor. The benefit: The defined and calibrated values are rendered exactly just seconds after the monitor is turned on and remain constant during the entire period of use. The sensor is invisibly integrated in the monitor.


Uniform brightness over the entire screen

The monitor shines thanks to its uniform illumination. This is down to the Digital Uniformity Equalizer (DUE), which corrects imbalances automatically, pixel by pixel. Gray tones of radiological and other medical images are correctly rendered over the entire display. This is vital for diagnostics.

Photograph: G-series without DUE
Without DUE
Photograph: G-series with DUE
With DUE

RX560-MD Mode
Select the Optimal Display Mode for Different Modalities

The CAL Switch functionality enables you to select from among many different display modes for different modalities, such as mammography, breast MRIs, ultrasound, or pathology examinations, without having to recalibrate each time.

Shipped with the monitor, the RadiCS LE software allows users to set modes in such a way that the optimal observation conditions are automatically activated, either via mouse click or through the monitor’s display mode.


Presence sensor: Save electricity when you are not in front of the monitor

Thanks to the presence sensor, you can save electricity and help protect the environment. The sensor registers whether someone is sitting in front of the screen or not. As soon as the person leaves the workstation, the monitor turns off automatically. When the person comes back, it turns back on – fully automatically, without touching the mouse or keyboard. It is always ready for use without a waiting period.

Foto: Ohne Präsenzsensor
Foto: Mit Präsenzsensor

Foto: Helligkeitsgarantie
Reliable brightness

EIZO is convinced of the quality of its products. The warranty for the monitors, therefore, also covers the brightness stability.


Foto: Software RadiCS
Consistently secure image quality

The optional EIZO RadiCS software to secure image quality enables extensive maintenance and testing of monitors and includes calibration, acceptance and constancy testing, and the archiving of all areas. If you are working on multiple stations, the use of the RadiNET Pro is recommended. This can be used to centrally control the calibration of all monitors, including data history. This saves you a significant amount of time and ensures consistently high image quality across the entire setup. The basic version RadiCS LE is already included with the RadiForce GX, RX, and MX/MS models.

Learn more about the RadiCS application classes

Learn more about RadiCS LE software (included in the delivery)

Learn more about RadiCS software (optionally available)

Learn more about RadiNet Pro software (optionally available)


Foto: graphic board MED-X90
For precise diagnoses: EIZO MED-X90 graphics card

The EIZO MED-X90 graphics card supports the properties, functions, and settings of the RadiForce RX560-MD optimally. It enables precise diagnostics and can control several monitors simultaneously. EIZO offers technical support and a warranty service for all graphics cards. Therefore, we recommend using EIZO graphics cards.

Display the specifications of the MED-X90


Five-year warranty

EIZO grants a five-year warranty. This is possible thanks to the highly developed production process based on a simple principle of success: sophisticated and innovative monitor technology, made from high-end materials.

Go to the warranty overview

Frequently asked questions
What tools does EIZO provide for quality assurance for image display devices in medical applications?

EIZO has developed the RadiCS software specifically for quality assurance for image display devices in the RadiForce range. It offers extensive tests and automatic alignment to guarantee constant and consistent image reproduction on all RadiForce LCD monitors, but also supports screens from other manufacturers. The software automatically executes test images and helps to perform measurements and assessments in accordance with the guidelines in a cost-effective and time-effective manner. For example, measurement results are automatically transferred to the documentation and archived and can be centrally managed using the optional RadiNET Pro software. A calendar with a reminder function ensures timely checks are performed. A suitable measurement device is required to measure the luminance, including veiling luminance. Measured values from various luminance meters are automatically read by RadiCS.

For what regions of the body and what methods or purpose is a RadiForce screen suitable in accordance with DIN 6868-157?

Depending on the body region / methods, different EIZO RadiForce screens are suitable for image display systems in accordance with DIN 6868-157. The EIZO RadiCS quality assurance software is divided into classes I to VIII. The following table shows a classification of suitable screens in this regard.

Note: An acceptance test is necessary for each image display system for an evaluation in accordance with DIN 6868-157.

What is the allocation of body regions / methods in accordance with DIN 6868-157 to RadiCS application classes and what are the minimum requirements for an image display device?

In accordance with DIN 6868-157, different minimum requirements are placed on image display devices depending on the body region / method. The EIZO RadiCS quality assurance software is divided into classes I to VIII. The following table shows a classification of the classes and minimum requirements in this regard.

Note: An acceptance test is necessary for each image display system for an evaluation in accordance with DIN 6868-157.

What does the DIN 6868-157 standard govern?

DIN V 6868-157. This DIN governs the acceptance test and constancy test for image display systems in radiography in order to ensure the necessary image quality.

From where can I obtain the QA guidelines?

From the Federal Ministry for the Environment, Nature Conservation and Nuclear Safety

Other FAQs on your product can be found in our FAQ section.

To the FAQs

Accessories
RadiCS
RadiCS

RadiCS quality assurance for RadiForce screens

RadiNET Pro
RadiNET Pro

RadiNET Pro for large hospitals

RadiLight
RadiLight

Comfort Light for Reading Rooms - Easily attachable light for RadiForce medical LCD monitors.

Top